On Thu, Oct 14, 2010 at 1:52 AM, Jacob Meuser <jakemsr@sdf.lonestar.org>
wrote:
B 0.00% usbtask
After urtw device removal:
% top -S -n 200 | grep usb
8 root 10 0 0K 19M sleep/0 usbtsk 0:00 0.00% usbtask
Then, after some time (not immediately on plugging in) it reverts to:
% top -S -n 200 | grep usb
8 root -6 0 0K 19M idle usbsyn 0:00 0.00% usbtask
With the rest of devices everything is OK.
Actually I'm using this dongle because booting proccess stopped on
trying to attach the WiMax part on Intel Link 5150. While that device
is connected via MiniPCIe, the WiMax part connects to the USB bus, so
I think that could be somehow connected. In 4.7 there were no issues
with Intel device, and urtw was faulty, but didn't give these
problems.
Yes. Regardless of usb port it attaches to the same EHCI hub and
behaves the same way.
Don't know whether it is somehow important or not, but power over usb
works for newly plugged devices that are not attached to the system.
--
Dmitrij D. Czarkoff