On 10/25/07, Francesco Toscan <francesco.toscan@gmail.com> wrote:
Thanks for your reply Francisco.
If the filesystem is screwed up then shouldn't the raid just ignore it
and run on 1 disk until I fix the problem? That seems like the
logical thing it should do unless all my mirrors of /var are messed
up.
Well anyways since it doesn't do that, some of my original questions
still stand. How can I be warned before a problem like this happens?
And lastly, is it possible in the worst case scenario if one of my
disks is completely fsck'ed up is it possible to run the system on 1
of the raid 1 disks until a second comes?
- J