I am not sure it has been said, but for a 4 disk raid10,f2 array
you should place the first and the second disk on one controller, and then the 3rd
and 4th on the second controller. Then you would have a copy of all blocks even
if one controller fails.
I believe the order is defined by the order the disks are specified in
on the mdadm --create line.
best regards
keld
On Mon, Apr 12, 2010 at 08:26:55PM -0700, Simon Matthews wrote: