As RapidIO is a switched network, the concept of 'previous' and 'next'
devices is invalid. Perhaps it's just the way they were
discovered/enumerated, but that does not matter any more at runtime. Or
at least, should not matter.
This can be extracted from the swpinfo field (which you removed in
another patch)?
Micha
--