Re: [PATCH 2/3][v2] blkio: Add io controller stats like

Previous message: [thread] [date] [author]
Next message: [thread] [date] [author]
From: Vivek Goyal
Date: Tuesday, April 6, 2010 - 6:47 am

On Mon, Apr 05, 2010 at 04:29:06PM -0700, Divyesh Shah wrote:

Most of the modern disks now seem to be be NCQ. But I guess we can keep
those stats as it is useful for you on non NCQ setup.


I am not sure if io_wait_time is cumulative by design. Think of this,
somebody says that this cgroup has waited for 1s on CFQ queue but actually
only .5 seconds have elapsed since the observation started.

So I would say that please document it very properly in blkio-controller.txt
so that it is clear what exactly these numbers represent and what to expect on
NCQ disks.

Thanks
Vivek
 
--
Previous message: [thread] [date] [author]
Next message: [thread] [date] [author]

Messages in current thread:
[PATCH 0/3][v2] blkio: IO controller stats, Divyesh Shah, (Fri Apr 2, 6:54 pm)
[PATCH 2/3][v2] blkio: Add io controller stats like, Divyesh Shah, (Fri Apr 2, 6:56 pm)
Re: [PATCH 2/3][v2] blkio: Add io controller stats like, Vivek Goyal, (Tue Apr 6, 6:47 am)
[No subject], Divyesh Shah, (Tue Apr 6, 10:00 am)