There is a HPET timer on that machine, but it is only available by
enforcing the address via black magic because the BIOS does advertise
it on the wrong location and the newest BIOS version does not
advertise it at all.
I have not seen a single bug report against PM timer aside of those K6
area systems, but we have
- HPETs which are not advertised at all
- HPETs which are advertised at the wrong address
- HPETs which do not count at all
- HPETs which tell us bogus operating frequencies
- HPETs which have bogus interrupt routings
So why should we rely on the HPET ?
The whole ACPI code relies pretty much on PM_TIMER and as I said
before there are no PM-TIMER related bug reports aside of those
documented K6 ones, which Alok did probably not know about and I
forgot them as well. Yeah, that's my fault.
Thanks,
tglx
--