Here are the errors I get, though look at it closer, I am don't appear to be
getting the reset, just this error from time to time:
sd 9:0:0:0: [sde] 976773168 512-byte hardware sectors (500108 MB)
sd 9:0:0:0: [sde] Write Protect is off
sd 9:0:0:0: [sde] Mode Sense: 00 3a 00 00
sd 9:0:0:0: [sde] Write cache: enabled, read cache: enabled, doesn't support DPO
or FUA
ata8.00: exception Emask 0x0 SAct 0x0 SErr 0x280000 action 0x0
ata8.00: BMDMA2 stat 0x687d8009
ata8.00: cmd 25/00:80:a7:00:1d/00:01:1d:00:00/e0 tag 0 cdb 0x0 data 196608 in
res 51/04:8f:98:01:1d/00:00:1d:00:00/f0 Emask 0x1 (device error)
ata8.00: configured for UDMA/100
ata8: EH complete
sd 7:0:0:0: [sdd] 976773168 512-byte hardware sectors (500108 MB)
sd 7:0:0:0: [sdd] Write Protect is off
sd 7:0:0:0: [sdd] Mode Sense: 00 3a 00 00
sd 7:0:0:0: [sdd] Write cache: enabled, read cache: enabled, doesn't support DPO
or FUA
I have 4 identical disks, with all 4 connected to the SIL controller all give
some errors, moving 2 of the disks to a promise controller makes the errors go
away on the 2 connected to the promise controller. All drives are part of a
software raid5 array.
Startup looks like this:
sata_sil 0000:00:09.0: version 2.3
ACPI: PCI Interrupt 0000:00:09.0[A] -> GSI 16 (level, low) -> IRQ 20
sata_sil 0000:00:09.0: Applying R_ERR on DMA activate FIS errata fix
scsi7 : sata_sil
scsi8 : sata_sil
scsi9 : sata_sil
scsi10 : sata_sil
ata8: SATA max UDMA/100 cmd 0xf8942080 ctl 0xf894208a bmdma 0xf8942000 irq 20
ata9: SATA max UDMA/100 cmd 0xf89420c0 ctl 0xf89420ca bmdma 0xf8942008 irq 20
ata10: SATA max UDMA/100 cmd 0xf8942280 ctl 0xf894228a bmdma 0xf8942200 irq 20
ata11: SATA max UDMA/100 cmd 0xf89422c0 ctl 0xf89422ca bmdma 0xf8942208 irq 20
Right now I am running 2.6.23.15-80.fc7, but have also got the errors under 2.6.23.1
Roger
--