Michael Tokarev wrote:
quoted text > Single Seagate 74Gb SCSI drive (10KRPM)
>
> BlkSz Trd linRd rndRd linWr rndWr linR/W rndR/W
> 4k 1 66.4 0.5 0.6 0.5 0.6/ 0.6 0.4/ 0.2
> 2 0.6 0.6 0.5/ 0.1
> 4 0.7 0.6 0.6/ 0.2
> 16k 1 84.8 2.0 2.5 1.9 2.5/ 2.5 1.6/ 0.6
> 2 2.3 2.1 2.0/ 0.6
> 4 2.7 2.5 2.3/ 0.6
> 64k 1 84.8 7.4 9.3 7.2 9.4/ 9.3 5.8/ 2.2
> 2 8.6 7.9 7.3/ 2.1
> 4 9.9 9.1 8.1/ 2.2
> 128k 1 84.8 13.6 16.7 12.9 16.9/16.6 10.6/ 3.9
> 2 15.6 14.4 13.5/ 3.2
> 4 17.9 16.4 15.7/ 2.7
> 512k 1 84.9 34.0 41.9 33.3 29.0/27.1 22.4/13.2
> 2 36.9 34.5 30.7/ 8.1
> 4 40.5 38.1 33.2/ 8.3
> 1024k 1 83.1 36.0 55.8 34.6 28.2/27.6 20.3/19.4
> 2 45.2 44.1 36.4/ 9.9
> 4 48.1 47.6 40.7/ 7.1
>
<snip>
quoted text > The only thing I don't understand is why with larger I/O block
> size we see write speed drop with multiple threads.
Huh? Your data table does not show larger block size dropping write
speed. 47.6 > 38.1 > 16.4.
quoted text > And in contrast to the above, here's another test run, now
> with Seagate SATA ST3250620AS ("desktop" class) 250GB
> 7200RPM drive:
>
> BlkSz Trd linRd rndRd linWr rndWr linR/W rndR/W
> 4k 1 47.5 0.3 0.5 0.3 0.3/ 0.3 0.1/ 0.1
> 2 0.3 0.3 0.2/ 0.1
> 4 0.3 0.3 0.2/ 0.2
> 16k 1 78.4 1.1 1.8 1.1 0.9/ 0.9 0.6/ 0.6
> 2 1.2 1.1 0.6/ 0.6
> 4 1.3 1.2 0.6/ 0.6
> 64k 1 78.4 4.3 6.7 4.0 3.5/ 3.5 2.1/ 2.2
> 2 4.5 4.1 2.2/ 2.3
> 4 4.7 4.2 2.3/ 2.4
> 128k 1 78.4 8.0 12.6 7.2 6.2/ 6.2 3.9/ 3.8
> 2 8.2 7.3 4.1/ 4.0
> 4 8.7 7.7 4.3/ 4.3
> 512k 1 78.5 23.1 34.0 20.3 17.1/17.1 11.3/10.7
> 2 23.5 20.6 11.3/11.4
> 4 24.7 21.3 11.6/11.8
> 1024k 1 78.4 34.1 33.5 24.6 19.6/19.5 16.0/12.7
> 2 33.3 24.6 15.4/13.8
> 4 34.3 25.0 14.7/15.0
>
> Here, the (total) I/O speed does not depend on the number
> of threads. From which I conclude that the drive does
> not reorder/optimize commands internally, even if NCQ is
> enabled (queue depth is 32).
While the difference does not appear to be as pronounced as with the WD
drive, the data does show more threads give more total IO. 4.7 > 4.5 >
4.3 in the 64k rndRd test, and the other tests show an increase with
more threads as well.
-
unsubscribe notice To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to
majordomo@vger.kernel.org
More majordomo info at
http://vger.kernel.org/majordomo-info.html
Please read the FAQ at
http://www.tux.org/lkml/
Messages in current thread:
Re: SATA RAID5 speed drop of 100 MB/s , Phillip Susi , (Thu Jul 5, 3:12 pm)