Re: [rfc] direct IO submission and completion scalability issues

!MAILaRCHIVE_VOTE_RePLACE
Previous message: [thread] [date] [author]
Next message: [thread] [date] [author]
To: Christoph Lameter <clameter@...>
Cc: Siddha, Suresh B <suresh.b.siddha@...>, <linux-kernel@...>, <arjan@...>, <mingo@...>, <npiggin@...>, <ak@...>, <jens.axboe@...>, <James.Bottomley@...>, <andrea@...>, <akpm@...>, <andrew.vasquez@...>
Date: Monday, July 30, 2007 - 4:35 pm

On Mon, Jul 30, 2007 at 11:20:04AM -0700, Christoph Lameter wrote:

We are looking into both SMP(multi-core) and NUMA systems.


If the device is capable of multi queues, then some of the control structures,
irqbalance can be done based on how those multi queues are distributed.


In the absence of specialized controllers, it is best to keep the control
structures close to the device node and move the I/O submission to this node.


Ok, there we have no other choice ;-)


So any suggestions for making this clean and acceptable to everyone?

thanks,
suresh
-
Previous message: [thread] [date] [author]
Next message: [thread] [date] [author]

Messages in current thread:
[rfc] direct IO submission and completion scalability issues, Siddha, Suresh B, (Fri Jul 27, 9:21 pm)
Re: [rfc] direct IO submission and completion scalability is..., Christoph Lameter, (Mon Jul 30, 2:20 pm)
Re: [rfc] direct IO submission and completion scalability is..., Siddha, Suresh B, (Mon Jul 30, 4:35 pm)